Double sided aluminum foil insulation is a light duty, utility Grade D/S Foil Insulation. It is made from 2 outer layers of pure aluminum foil and 1 layer thicker natural kraft paper. These layers are bonded together with polyethylene and reinforced with 3-way fiberglass scrim.

Double sided aluminum foil insulation is ideally used as sarking and insulation under roofs, in walls behind cladding or under timber floors, for residential and commercial building. Combining with glass-wool /rockwool/ mineral wool/ foam insulation, it  is excellent as a vapor barrier for air-conditioning ducts, pipes and vessels.

Aluminum Foil Insulation Composition:

Composition

Description

Value (English)

Value (Metric)

Foil

Aluminum

0.28 mil

7 micron

Reinforcing – MD

Fiberglass

 2/inch

 8/100mm

Reinforcing – MD

Fiberglass

3/inch

12/100mm

Adhesive

Polyethylene

 

 

Kraft

Natural

36.8Ibs/3000ft2

60gsm

Adhesive

Polyethylene

 

 

Foil

Aluminum

0.28 mil

7 micron

 

 

Aluminum Foil Insulation Properties:

Physical properties

Test Method

Value (English)

Value (Metric)

Basis weight

Scale

25.5lbs / 1000 ft2

125gsm

Permeance (WVTR)

ASTM E96,

Procedure A

0.02 perm

1.15 ng/N.s

Tensile Strength-MD

ASTM D828

35.2 lbs / In

155 N/25mm

Tensile Strength-XD

ASTM D828

19.3lbs / In

85 N/25mm

Burst Strength

ASTM D774

52.2psi

36 N/cm2

Low temperature

Resistance

ASTM D1790

4 hrs @

-40℉ (-40℃)

Remains Flexible

No Delamination

Remains Flexible

No Delamination

High temperature

Resistance

ASTM D1790

4 hrs @

+240℉ (+116℃)

Remains Flexible

No Delamination

Remains Flexible

No Delamination

Emissivity

ASTM E408

0.03

0.03

Fire Rating

BS476Pt6.7

Class 1

Class 1

 

Available Roll Width: 1.25m,1.35m

Remarks

1.The data above are typical values only, and should not be used for specifications purpose.
2.Tolerance: Weight and Thickness: ±10%;Width:±3mm; Length: Log Roll: ±0.3m, Jumbo Roll: ±0.5%.
3.Double sided aluminum foil insulation should be stored at room temperature, kept away from wet and heat source.
4.The users should take test and do trial-application on the above products before coming into application so as to witness and ensure suitability for their special purpose and technique.